Spacer type and spacing
01
Spacers hold the reinforcement off the form face. Too few, wrongly spaced, or the wrong height, and the cage sits lower than the drawing intended between the supports.

Precast Concrete · Durability
Concrete cover is the depth of concrete between the outer face of an element and the nearest reinforcement. It is specified to protect the steel from corrosion, and it is the characteristic most directly responsible for how long a structure lasts in its exposure environment.
Unlike most quality characteristics, insufficient cover produces no immediate symptom. The element looks correct, performs correctly and passes its strength tests, and the consequence appears years later as cracking and spalling along the line of the bars.
Zabidou verifies the position of the cage, the spacers and the cast-in items while the mould is still open, which is the one window in which cover can still be corrected.
Zabidou in production today
QLD + VIC
Operating in factories across Queensland and Victoria today.
100%
Inspection coverage on finished items as they come off the line.
Silver
Associate Member, Australian Steel Institute.
Bronze
Member, National Precast Association Australia.
Cover is specified as a number, and achieved through three physical things that all happen before the pour. Each of them is adjustable and each of them moves.
01
Spacers hold the reinforcement off the form face. Too few, wrongly spaced, or the wrong height, and the cage sits lower than the drawing intended between the supports.
02
A cage that flexes under the weight of concrete or under a vibrator moves during the pour. The cover measured before placing is not the cover that results.
03
Vibrators leaned against the cage, concrete dropped onto it, or operatives standing on the steel will all displace reinforcement after it has been inspected and signed off.
Cover has a specific and awkward property: the only moment it can be checked easily is the moment before it becomes permanent, and that moment is under more time pressure than any other in the process.
01
Cover can be verified directly while the cage is in the mould and the pour has not started. Once concrete is placed, the direct check is gone.
02
A cover meter will locate bars and estimate depth through hardened concrete. That is a deliberate exercise with equipment and a trained operator, not something done routinely across production.
03
A low-cover element is indistinguishable from a correct one. There is no mark, no sound and no dimension out of tolerance, so nothing prompts anyone to look.
The practical conclusion is that cover is a pre-pour problem, and anything that improves it has to act before the concrete goes in. That is where Zabidou measures.
That is set-out verification: confirming that the cage, the spacers and the cast-in items are where the drawing puts them, while the mould is still open and a correction costs a few minutes.
Zabidou verifies component position before and during production, with the mould still open, and records the result against that element. Where the reinforcement or a cast-in item sits outside tolerance the operator sees it at the station rather than discovering it later.
Two honest limits. This checks position before the pour, not cover through hardened concrete, so it does not replace a cover meter where one is specified. And it cannot see movement that happens during placing, although a measurement taken immediately before the pour narrows that window considerably.
For the plant, that means a cover problem costs a few minutes at the station rather than becoming a durability question raised years later with no way left to answer it.
The same check runs on a precast concrete bed and on a steel fabrication line, where the equivalent characteristic is the position of cleats, holes and cast-in items against the drawing.
Cover is also lost where honeycombing reaches the reinforcement, and it is a natural hold point in the inspection and test plan before the pour.
Five checks run as the element is produced, and the set-out verification among them is the one that carries cover, confirming component position while a correction still costs minutes.
Complete 3D measurement and verification of as-built output against a Golden Sample or design intent, for full dimensional compliance without stopping the line.
Automated, real-time verification that components are correctly positioned before and during production, while the mould is still open or the section is still in the jig.
Inline detection of surface defects, voids and irregularities at industrial speed, fully automated and without manual inspection.
Precise measurement and verification of critical dimensions against a Golden Sample or the drawings, inline, in real time, at scale.
Manufactured-unit centric digital provenance that automatically delivers the full audit history operations, financiers and customers demand.
The same characteristic, examined at three points in the life of an element. The cost of acting rises sharply across the row.
| Before the pour | After demould | After installation | |
|---|---|---|---|
| How it is checked | Direct measurement of the cage and spacers. | A cover meter over the hardened face. | A cover meter, with access arranged. |
| What it takes | Minutes, while the mould is open. | Equipment and a trained operator. | Access, scaffolding or traffic management. |
| If it is wrong | Adjust the spacers and re-check. | Disposition the element: concession or recast. | Assessment, and potentially remedial works. |
| Who is involved | The operator at the station. | Quality, and the design engineer. | The asset owner and their engineer. |


Concrete cover is the depth of concrete between the outside face of an element and the nearest surface of the reinforcement. It is specified to protect the steel from corrosion and to provide fire resistance.
It is sometimes called cover depth or nominal cover, and the required value comes from the exposure classification and the design standard applying to the element.
It is the principal protection for the reinforcement. Insufficient cover allows moisture, chlorides and carbon dioxide to reach the steel sooner, which leads to corrosion, expansion and eventually cracking and spalling of the surrounding concrete.
Because the consequence appears years later, inadequate cover is a durability failure rather than a performance one, and it will not be detected by strength testing.
Before the pour it is measured directly, from the form face to the reinforcement, with spacers providing the intended separation. After the concrete has hardened it is measured with a cover meter, which locates the bars electromagnetically and estimates their depth.
The two methods answer the same question at very different cost, which is why the pre-pour check is the one worth getting right.
Spacers that are the wrong height, too few or badly spaced; a cage that flexes or lifts during placing; and reinforcement displaced by vibration, by concrete being dropped onto it or by people standing on it.
In most cases the cover was correct when it was inspected and changed afterwards, which is why a single pre-pour sign-off is not always sufficient.
It can verify the position of reinforcement and cast-in items before and during production, while the mould is still open, which is where cover is determined.
It does not measure cover through hardened concrete. Where the specification calls for cover meter readings on finished elements, that remains a separate exercise.